TS 248/TS 260

    Specifications

    Cable

    Workpiece touch probe

    TS 248

    TS 260

    TS 150

    Probe accuracy

    ±5 µm with use of the T404 standard stylus

    Probe repeatability

    Repeated probing from one direction

    2 s 1 µm at a probing velocity of 1 m/min

    Typical values:

    2 s 1 µm at a probing velocity of 3 m/min

    2 s 4 µm at a probing velocity of 5 m/min

    Deflection of probe contact

    5 mm in all directions (with stylus length L = 40 mm)

    Deflection forces

    Axial:  8 N (TS 248:  4 N)

    Radial:  1 N (TS 248:  0.5 N)

    Probing velocity

    5 m/min

    Protection EN 60529

    IP68

    Operating temperature

    10 °C to 40 °C

    Storage temperature

    –20 °C to 70 °C

    Mass without taper shank

     0.15 kg

     0.1 kg

    Fastening*

    • With taper shank1) (only with radial flange socket)
    • Via M28x0.75 external thread
    • Via coupling joint with M22x1 external thread
    • Via M16x1 external thread on the mounting base
    • Contact on the mounting base
    • Axial cable outlet: M22x1 for fastening to the machine
    • Radial cable outlet: Fastened to the machine with four M3 screws

    Electrical connection*

    8-pin M12 flange socket, axial or radial

    Two-pole sliding contact on the mounting base

    Cable length

    25 m

    Supply voltage2)

    DC 15 V to 30 V/ 100 mA (without load)

    DC 15 V to 30 V/ 85 mA (without load)

    Output signals2)

    • Trigger signals S and S (square-wave signal and its inverted signal)
    • Floating trigger output

    HTL signal levels2)

    UH 20 V at –IH 20 mA

    UL 2.8 V at IL 20 mA

    at rated voltage of DC 24 V

    Signal transmission

    Cable

    * Please select when ordering

    1) See Mounting on page 18

    2) With the TS 150: over the UTI 150