- Specifications
- Documentation
IK 220 |
||||
Encoder inputs |
15-pin D-sub connections (male, X1 and X2), for two encoders |
|||
Input signals (switchable) |
1 VPP |
11 µAPP |
EnDat 2.1 |
SSI |
Input frequency |
≤ 500 kHz |
≤ 33 kHz |
– |
|
Cable length1) |
≤ 60 m |
≤ 10 m |
||
Adjustment of encoder signals |
Adjustment of offset, phase, and amplitude by the software |
|||
Signal subdivision |
4096-fold |
|||
Data register for measured values |
48 bits; of which only 44 bits are used for the measured value |
|||
Internal memory |
For 8192 position values |
|||
Measured-value trigger |
Through the following (selectable):
|
|||
Access time to measured values |
|
Depends on the encoder |
||
Interface |
PCI bus (plug and play) Local Bus Specification Rev. 2.1 |
|||
Software driver and demonstration program |
For Windows 7 (32-bit and 64-bit) In VISUAL C++, VISUAL BASIC, and BORLAND DELPHI included in delivery Via download: Windows 10 (64-bit) |
|||
Outputs for encoder signals |
11 µAPP Via PCB connector on the IK (10-pin, female) Fitting cable assembly with PC-slot cover optionally available |
|||
Power consumption |
Approx. 4 W, without encoders |
|||
Dimensions |
190 mm x 100 mm |
|||
Operating temperature |
0 °C to 55 °C (storage temperature: –30 °C to 70 °C) |
|||
1) With HEIDENHAIN cable; longer cable lengths upon request |